X1 No clean water or little clean water sprayed out from the base station
Model | X1 |
Malfunction phenomenon | No clean water or little clean water sprayed out from the base station. (2-1) |
Troubleshooting | 1. Use the base station to self-clean and observe the water output. 2. Check whether the sealing ring of the clean water bucket is skewed or sunk, and reinstall it. 3. Check whether the filter plug of the clean water bucket is normal. 4. Reinstall the sealing plug of the clean water bucket. |
Picture/Video |
Maintenance Plan | 1. Replace the sealing plug of the water tank. 2. Check whether the water flow module is installed properly. 3. Check whether there is water inside the base station. 4. Disassemble the machine to check whether the water pipe and electromagnetic pump wires are installed properly. 5. Replace the electromagnetic pump to test. 6. If it is invalid to replace the electromagnetic pump, please replace the mainboard of the base station to test. |
Picture/Video |