X1 No clean water or little clean water sprayed out from the base station

2022-04-16

Model

X1

Malfunction   phenomenon

No clean water or little clean water sprayed out from the base   station. (2-1)

Troubleshooting

1.   Use the base station to self-clean and observe the water output.

2.   Check whether the sealing ring of the clean water bucket is skewed or sunk,   and reinstall it.

3.   Check whether the filter plug of the clean water bucket is normal.

4.   Reinstall the sealing plug of the clean water bucket.

Picture/Video

Maintenance Plan

1. Replace the sealing plug of the water tank.

2. Check whether the water flow module is installed properly.

3. Check whether there is water inside the base station.

4. Disassemble the machine to check whether the water pipe and   electromagnetic pump wires are installed properly.

5. Replace the electromagnetic pump to test.

6. If it is invalid to replace the electromagnetic pump, please   replace the mainboard of the base station to test.